Hoyles Cig-Arrete Stand Alone W'proof Flame Detector Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Hoyles Cig-Arrete Stand Alone W'proof Flame Detector. Hoyles Cig-Arrete Stand Alone W'proof Flame Detector/Voice Sounder User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
See how Cig-Arrête
®
Tobacco Detection Systems
can work for you
by viewing our demo videos at:
“Please do not smoke
In this area ”
“Smoking in School is not
permitted”
Cig-Arrête Weatherproof Master Flame Detector with Voice Sounder (Part No CSA-FDW)
Designed for the detection of unauthorised smoking in external
areas subject to high winds, rapid ventilation, smoke and gas.
Typical applications include open areas, building entry/exit
points, rooms with high ceilings (>3m <6m), or locations sub-
ject to intermittent smoke or vapour.
The module is designed for single applications, and will detect a
25mm cigarette lighter flame at 6 metres within 1 second. When
installed as part of a Cig-Arrête Tobacco Control System, the
CSA-FDW can be connected to Weatherproof Slave Flame Detec-
tion units (CSA-FDWS) to provide complete coverage.
Coverage 6m @120° FOV
Product Features
Designed to detect a flame lighting a cigarette with 120 degree field of view
Fully self-contained, battery operated flame detector with Voice Sounder
Operates from 4 x AA standard alkaline battery with full remote control.
SmartWave
©
drive system provides clear voice message at 90dB output in alarm
User programmable with any voice message using Windows PC. (up to 100 messages)
Tough, aesthetic, IP54 enclosure
On board relay for connection to remote equipment (contacts rated at 1A 24v dc)
May be remotely powered using an optional 6V power supply (part CSA-006)
The table below shows the coverage area at the installation height.
Height Coverage Height Coverage
Metres (x) Metres (y) Feet (x) Feet (y)
1 3.5 3 10
2 7 6 20
3 10 9 31
4 14 12 42
5 17 15 52
6 21 18 62
Typical Applications
Hospital Entrances
Ambulance Bays
Factory Gates
School Shelters
Playgrounds